Requirements for residential premises


Article 50. Requirements for residential premises

A comment :

1. According to the content of the commented article, criteria are established for residential premises that are provided to a person for residence. It must be well-equipped in relation to the conditions of a given locality and meet established sanitary and technical requirements.

Sanitary and technical requirements provide conditions under which a person can live without harm to her health. Landscaping is determined by the presence of communal amenities in the residential premises (water supply, sewerage, heating, gas supply, etc.).

Thus, a room may meet sanitary and technical requirements, but be disorderly, and vice versa. It should be taken into account that the level of improvement in different settlements and localities is different.

Therefore, the legislation connects the solution to the issue of the convenience of the provided residential premises with the specific conditions of the locality in which it was provided.

2. Residential premises provided to a citizen who is on the housing register do not necessarily have to be located in a new house. Vacant residential premises may also be provided if they meet the established requirements.

Providing citizens with residential premises that do not meet the established requirements is permitted only in cases of temporary improvement of housing conditions in the manner prescribed by the Apartment Registration Rules.

In particular, according to paragraph.

54 of the Rules, in some cases, at the request of citizens who are on the housing register (primarily those who have a priority for receiving residential premises), and citizens enjoying the right of priority receipt of residential premises in order to temporarily improve housing conditions, they may be provided with residential premises , which does not meet the requirements for livability, sanitary and technical requirements provided for, with the corresponding retention of the right to be registered and on the priority list or on the non-priority list.

3. According to Part 2 of Art. of the commented article, when providing residential premises, it is not allowed to occupy one room by persons of different sexes, over nine years of age, except for spouses. Apartment registration rules (clause

52) an additional ban has been established regarding the occupancy of one room by persons suffering from severe forms of certain chronic diseases, and therefore cannot live in the same room with members of their family.

It is also not allowed for an apartment built for one family to be occupied by two or more families or two or more single persons, except in cases provided for in Article 54 of the Housing Code of Ukraine.

The procedure for providing isolated living space that has been vacated in an apartment in which two or more tenants live (in a communal apartment), established in Art. 54 Residential Complex of the RSFSR.

It is general and applies to residential premises vacated in apartments built for one family.

If, according to this Procedure, an isolated residential premises, a vacated one (room, rooms) cannot be transferred to the tenant living in this apartment, it is provided to other persons. Thus, as an exception, another family or a single person may additionally move into an apartment built for one family.

Elderly persons, as well as corresponding categories of disabled and sick people, at their request, are provided with living quarters on the lower floors or in buildings with elevators.

The elderly referred to in the article include persons entitled to receive a pension on a general basis: men who have reached 60 years of age, women - 55 years of age.

The right of disabled people to receive living space on the ground floor or in a building equipped with an elevator is established by the medical advisory commission of the relevant medical institution.

On this information and legal website you can find everything you need to effectively implement your issue: comments on national laws, all major legislative acts, procedural documentation templates, a dictionary of legal terms, cases of court consideration and addresses of competent authorities and institutions Ukraine.

The national legal website of Law of Ukraine LLC provides an exceptional opportunity for you to get qualified legal advice - online legal advice from our professional lawyers. In general, if you are faced with a legal issue and you need professional legal assistance, fill out the question form. We will do everything to ensure that your rights and interests are reliably protected!

Housing law

The above characteristics were developed in the Decree of the Government of the Russian Federation of January 28, 2006 No. 47 “On approval of the Regulations on recognizing premises as residential premises, residential premises unsuitable for habitation and an apartment building as unsafe and subject to demolition or reconstruction” (as amended on 02.08. 2007 No. 494) (hereinafter referred to as the Regulations).

  • load-bearing and enclosing structures of residential premises, including those that are part of the common property of the owners of premises in an apartment building, must be in working condition in which violations that arise during operation in terms of deformability (and in reinforced concrete structures - in terms of crack resistance) do not lead to disruption of the performance and load-bearing capacity of structures, the reliability of a residential building and ensure the safe stay of citizens and the safety of engineering equipment;
  • the foundations and load-bearing structures of a residential building, as well as the foundations and load-bearing structures that are part of the common property of the owners of premises in an apartment building, must not have destruction or damage leading to their deformation or the formation of cracks, reducing their load-bearing capacity and impairing the operational properties of the structures or residential building as a whole;
  • residential premises, as well as the common property of premises owners in an apartment building, must be arranged and equipped in such a way as to prevent the risk of injury to residents when moving in and around the residential premises;
  • residential premises must be provided with engineering systems (electric lighting, drinking and hot water supply, drainage, heating and ventilation, and in gasified areas also gas supply);
  • engineering systems (ventilation, heating, water supply, drainage, elevators, etc.), equipment and mechanisms located in residential premises, as well as those included in the common property of premises owners in an apartment building, must comply with sanitary and epidemiological safety requirements;
  • external enclosing structures of residential premises, which are part of the common property of the owners of premises in an apartment building, must have thermal insulation that ensures in the cold season the relative humidity in the inter-apartment corridor and living rooms is no more than 60 percent, the temperature of heated premises is not less than +18 degrees Celsius, as well as insulation from the penetration of external cold air, vapor barrier from the diffusion of water vapor from the room, ensuring the absence of moisture condensation on the internal surfaces of non-transparent enclosing structures and preventing the accumulation of excess moisture in the structures of a residential building;
  • residential premises, as well as premises that are part of the common property of premises owners in an apartment building, must be protected from the penetration of rain, melt and ground water and possible domestic water leaks from engineering systems using structural means and technical devices;
  • access to residential premises located in an apartment building above the fifth floor, with the exception of the attic floor, must be via an elevator;
  • and others.

The procedure for preparing documents to recognize the suitability of a house for habitation

First of all, you should register ownership of the property; this can be done by contacting the MFC. Without entering information about ownership into the unified register, it is impossible to carry out the procedure for recognizing a house as residential.

Read more: How to get diapers for a group 1 disabled person for free

The next document that needs to be completed is the BTI technical passport. This is a document that contains all the characteristics of the house (room plan, dimensions, design features). Based on the technical passport, examinations are carried out and the necessary conclusions are issued.

To obtain a technical passport, the owner needs to write an application to the BTI and pay a state fee. An on-site specialist will inspect the building, site and surrounding area and check documents.

Based on this survey, BTI will prepare a technical passport for the structure.

Information in the technical passport can serve as the basis for recognizing a garden house as residential if the relevant information is specified there.

These two documents are required both in case of legal proceedings and when applying to the regional executive authority.

Requirements for kindergartens

For kindergartens, a separate SanPiN 2.4.1.3049 13 is used.

This act establishes requirements for:

Source: https://KPPKDirection.ru/nezhilaya/tehnicheskie-normy-zhilogo-pomeshcheniya.html

SanPiN norms - what is it?

“Sanitary and epidemiological requirements for living conditions in residential buildings and premises” or SanPiN were approved by the Chief Sanitary Doctor of the Russian Federation on August 24, 2010, and, in fact, are the main document regulating compliance with sanitary standards in residential buildings.

In simple and understandable language, local authorities control compliance with this particular document, and it is this document that is the fundamental set of rules for compliance.

It should be noted here:

  1. A number of provisions of the new SanPiN are contrary to the current laws of the Russian Federation, for example, in order to open a store on the first floor of a residential premises in accordance with SanPiN, permission is not required, but it will be required in accordance with the Rules for the transfer of residential premises to non-residential premises and the Housing Code. It is possible that residents will have to prove their case in the courts. Federal laws have greater force than rules, which are secondary legislation.
  2. In order to exercise this same control, residents need to contact local authorities with a complaint about violations. They themselves, according to the provisions of the rules, are not obliged to do this.

Some of the general provisions

  1. SanPiN standards apply only to residential buildings intended for permanent residence, and do not apply to residential premises of hostels, hotels, homes for the disabled and shelters, and rotational camps.
  2. The rules are mandatory for everyone.
  3. The norms of these rules apply to citizens, individual entrepreneurs and legal entities - everyone involved in the design, construction, maintenance of residential premises, as well as those who monitor their compliance.

Hygienic requirements

The rules are divided into 9 sections, each of which imposes certain hygienic requirements for one or another aspect of the maintenance of residential premises and local areas. These rules repeat those in force since 2000, but there are also a number of changes designed to make living in residential buildings more comfortable.

Some features of the requirements for the site and territory of residential buildings:

  1. Standards for planting trees and shrubs near residential buildings have been identified. Trees with a large crown should be planted at a distance of at least 5 meters from the building; if the crown is larger, then the tree must be planted further from the wall. Regarding shrubs, the rule is this: they are planted 1.5 m from the wall and the height of their crown should not reach the lower edge of the window opening on the first floor.
  2. It is planned to equip the territory and strictly distribute recreation areas for children to play, green spaces, guest parking, pedestrian and driveway paths.
  3. Pedestrian paths, driveways, and parking lots must have a hard surface, and the parking lot must also have drainage.
  4. The placement of departmental parking lots is prohibited, but nothing is said about commercial ones.

The through movement of heavy vehicles through the local area is also prohibited.

Specific requirements for residential premises

  1. The rules prohibit the installation of garbage chutes and other engineering structures directly above living rooms.
  2. It is prohibited to place toilets in apartments with an entrance directly into the living room or kitchen, as well as above them, with the exception of two-level apartments and toilets located directly next to the bedroom.
  3. It is prohibited to install apartments on ground floors and basements.
  4. It is planned to install storage rooms and utility rooms in them.
  5. In houses above 5 floors, an elevator is required (nothing new here).
  6. Formally, the establishment of shops and other public premises on the first floors of houses is permitted; in this case, compliance with sound, noise and vibration insulation standards and the installation of special goods receivers is mandatory.
  7. Industrial production devices are prohibited in houses.
  8. The installation of garages in the basement floors is possible if there is a buffer floor on which it is prohibited to place children's institutions and treatment rooms.

Heating, ventilation, microclimate

There are no special changes or additions to heating, ventilation, microclimate and air environment compared to the previous rules.

Heat standards in apartments are provided for in a special appendix to the rules:

  1. It is prescribed to enclose heating devices if their surface is above +750C and to install heated floors on the first floors.
  2. In principle, it is possible to install autonomous heating if it does not pollute the environment and does not create noise beyond what is required.
  3. It is prohibited to connect the ventilation system of two different apartments; ideally, if the plumber combined your bathtub and your neighbors’ bathtub on the grounds that the ventilation shaft is clogged, you can complain - this is a violation of the rules.

Ventilation of rooms should be separate from the kitchen and bathroom; it is assumed that a central ventilation system is installed in the kitchen and bathroom, which extends 1 m above the roof ridge.

Lighting and insolation

  1. The standards for insolation (natural sunlight) and lighting of rooms and other premises are described in detail by latitude and individual rooms.
  2. An interesting innovation is the insolation standards for children's playgrounds; in fact, they should be located on the sunny side of the house and not be shaded by other objects.
  3. The rules require illumination at night of the entrance doors of the house and the area in front of them, as well as pedestrian paths and playgrounds.

About the level of noise, vibration, etc.

Calculation of acceptable levels of sound pressure, vibration, infrasound, electromagnetic and electric fields are given in separate annexes, and general provisions are written out in the text of the rules. It is believed that these standards are designed to protect the health of the residents of each particular house.

Requirements for interior decoration

The requirements for interior decoration actually affect three aspects: permissible standards for chemical substances released into the air, electrostatic voltage and natural radionuclides and are designed to protect residents from their possible harmful influences.

Requirements for water supply and sewerage

Contains standards providing for the provision of drinking and household water to residents, as well as the installation of sewerage systems in accordance with sanitary standards and the separation of sewer ventilation and chimneys

Requirements for waste and debris disposal

  1. Rules have been written for the design, maintenance and operation of a garbage chute if it is present in the house, in particular, there is a clause about a separate entrance door to the garbage chute chamber and the tightness of the system; in case of poor insulation and an unpleasant odor on the floors, this clause can serve as a basis for complaints.
  2. Separately, the construction of a site for garbage containers is prescribed, where a hard surface, green spaces around the perimeter and daily garbage removal are prescribed.

Content requirements

The requirements for the maintenance of apartments and the house as a whole are spelled out very clearly and extremely clearly:

  1. It is prohibited to use the premises for other purposes, for example, to set up production (the project does not provide for such use of residential buildings).
  2. A separate clause includes a ban on storing harmful chemicals.
  3. It is not permitted to carry out work that will disturb residents of neighboring premises or exceed the permissible noise and dust levels.
  4. It is prohibited to place objects and things that disturb other residents in public places, for example, corridors, staircases, and there is also a ban on flooding neighbors’ apartments.
  5. The rules oblige you to monitor the serviceability of engineering systems - water supply and sewerage.

Measures should be taken to prevent infectious diseases and exterminate rodents and various insects, such as cockroaches.

Requirements for residential premises - State and law

Every person has the right to live in optimal living conditions. Therefore, certain requirements are imposed on any residential premises. To do this, numerous norms and rules of SanPiN are taken into account.

If they are violated, then this is the basis for registering citizens living in such conditions as those in need of housing. Therefore, the state should try in various ways to prevent the presence of such housing.

Requirements for residential premises include many aspects, which include:

  • availability and condition of utilities;
  • location of the residential property;
  • features of the local area.

Where are the requirements stated?

When studying the condition of each room, the provisions of SanPiN 2.1.2.2645-10 are taken into account. These sanitary standards were adopted in 2010. This act is called “Requirements for living conditions in residential premises.” It is on them that a special interdepartmental commission is guided, determining the suitability of a particular premises for habitation.

The document lists the basic conditions, as well as requirements for the safety and comfort of living of citizens. The nuances of performing repair work or finishing the premises are given. SanPiN regulates numerous issues, which include:

  • the conditions on the basis of which citizens are provided with living quarters after completion of construction work;
  • standards observed by homeowners when operating premises, and they are developed during the design process of the building;
  • requirements for the process of reconstruction of structures;
  • rules and regulations observed even before the construction process;
  • requirements that operating enterprises must meet.

SanPiN requirements apply not only to apartment buildings, but also to various hotels or hostels, as well as to residential buildings with a special purpose.

The procedure for recognizing premises as residential when a citizen applies to the MFC

The administration of a settlement or district, by order, creates an interdepartmental commission to conduct a comprehensive survey and establish the real condition of the premises. An employee of the district administration is appointed as the chairman of the commission.

The interdepartmental commission includes members of the following organizations:

  • departments responsible for housing control;
  • sanitary-epidemiological service;
  • Ministry of Emergency Situations, which oversees fire safety of buildings;
  • representatives of architectural supervision, urban planning, design experts and other representatives (if required by a specific case).

The interdepartmental commission determines the documents that the applicant must provide in order to recognize the property as suitable for habitation.

After the commission has carried out surveys and examinations, a conclusion is drawn up and signed by its participants on the compliance or non-compliance of the inspected real estate with the requirements of the Regulations on the recognition of premises as residential premises. If the commission does not recognize the premises as residential, the citizen must go to court.

What to do if the developer goes bankrupt?

There are often situations when citizens prefer to purchase real estate from a developer. In this case, they form a DDU with the construction company.

Based on this document, the developer must transfer the finished residential property to the buyers within a specific time frame. But sometimes a company declares itself bankrupt.

In this case, the house may already be completed, but the company does not have time to put it into operation.

Under such conditions, it is optimal for buyers to submit an application for a requirement to transfer the residential premises to the buyer. It is sent to the court, which is considering a specific bankruptcy case.

It creates a register of requirements for the transfer of residential premises. It is represented by a special list of requirements of all creditors. This document is studied by the court to determine what demands are being made by the plaintiffs.

They must be confirmed by official documents.

The register of requirements for residential premises includes the claims of all buyers of apartments under the DDU. Such a register was introduced on the basis of Federal Law No. 210.

Under such conditions, a specific bankruptcy procedure for a construction company is used, so not only the property is sold, but also finished objects are issued to buyers.

The requirement to transfer residential premises will be appropriate and legal if the developer completed the property before declaring bankruptcy.

What is required to be included in the registry?

Initially, the developer must declare bankruptcy. Next, the observation procedure begins, during which all creditors can present their claims. It is at this time that there is an opportunity to include requirements for the transfer of residential premises in the register. To do this, the shareholder must have documents submitted to the court:

  • a correctly drawn up application for inclusion in the register of residential premises requirements;
  • DDU drawn up with a bankrupt developer;
  • document confirming payment for residential premises.

It is important not to miss the deadline set for filing an application, since from the moment of publication of information about the bankruptcy of the developer, the process can only be completed within two months. Documents are submitted to the arbitration court dealing with a specific bankruptcy case.

If there are grounds for inclusion in the register, then the shareholder is included among the creditors. By a court decision, the creditors' claims are satisfied, so the shareholder can receive a finished apartment, but at the same time it must meet numerous sanitary requirements.

Also, by court decision, the house can be completed if it has not yet been put into operation. Often it is sold to a new developer.

Source: https://uk-mishino.ru/nezhilaya-sobstvennost/trebovaniya-predyavlyaemye-k-zhilomu-pomeshcheniyu.html

Determining a suitable premises for habitation

A residential building is considered a building with several rooms, utility rooms, a kitchen, a bathroom, a toilet, intended for the permanent residence of people, providing them with all the necessary living conditions.

Residential premises are recognized as real estate located inside a building in which citizens can live during the calendar year.

A building is considered suitable for habitation and can be a permanent place of residence for citizens if it is made in accordance with the requirements of the following documents:

  • MDS position 13-21. 07;
  • SNiP 31-02-2001;
  • SanPiN 2.1.2.2645 10;
  • several joint ventures with fire safety regulations.

It is impossible to recognize as residential:

  • technical construction;
  • common areas, including basements and entrances.

Basic requirements for habitable real estate

  1. To be considered residential and suitable for living, the frame and walls of the house in question must have strength that ensures the safety of the structure. External walls must have sufficient heat and vapor barrier. In winter, indoor humidity should not exceed 60%, and the temperature should not drop below 18 degrees.
  2. The premises must meet the requirements of SNiP 31-02-2001 for the width of rooms and corridors, the size of the kitchen and toilet. The area of ​​the rooms is no less - 12 m2, kitchen - 6 m2, bedrooms - 8 m2. The width of the corridors is less than 0.85 m, kitchen 1.7 m, hallway 1.4 m, bathroom 1.5 m, toilet 0.8 m.
  3. The building must be located on a plot of land in a residential area of ​​the settlement.
  4. The height of the ceilings inside the building must be at least 2.5 meters, and in the hallway and corridor this value can be reduced to 2.1 meters, provided that there are mezzanines on the ceiling.
  5. It is not allowed to have stair steps of different heights, as this may result in injury to occupants.
  6. Rooms and kitchens should have windows and be naturally lit during the day.
  7. The room is protected from rain, melt or groundwater getting inside.
  8. The following utilities must be installed in a residential building:
  • electricity supply;
  • water supply (sufficiently cold);
  • heating;
  • ventilation;
  • sewerage (use of septic tanks is possible);
  • gas supply (if the area where the building is located is gasified).
  1. The level of sound and vibration inside housing must be within acceptable standard values. And the content of harmful substances is less than the values ​​hazardous to health.
  2. Living rooms should not be located above the toilet, bathroom or kitchen.

If the house fully complies with all the listed requirements, it can be recognized as residential in court or by an interdepartmental commission specially organized for this purpose.

Sanitary and technical requirements for residential buildings

Builder's website

When designing residential buildings, 3-hour insolation should be provided for all apartments whose windows face the illuminated part of the horizon sector from 50 to 310.

When the living rooms of apartments are oriented on both sides to a shaded sector, it is allowed to orient no more than one room of two- and three-room apartments; two rooms - four- and five-room apartments.

All living rooms and kitchens should have natural lighting based on the ratio of the area of ​​light openings to the area of ​​rooms and kitchens in the range from 1:5 to 1:8. The area of ​​the glazed part of windows and balcony doors is taken as the calculated area of ​​the light opening.

Painting or wallpapering residential premises should be done taking into account the orientation of the premises: to the north - with light colors in warm colors, to the south - with cool tones.

Common corridors longer than 12 m must be provided with natural light and ventilation, and the window area must be at least 1:16 of the floor area of ​​the corridor. The maximum length of corridors illuminated from one end should be 20 m, when illuminated from two ends - 48 m, with longer lengths it is necessary to install light pockets (halls) every 20 m.

Residential apartments must be provided with cross or corner ventilation; It is allowed to ventilate one-sided one- and two-room apartments through the staircase - and there should be no more than two such apartments on the floor.

In high-rise residential buildings, electrification of kitchen equipment should be provided. Exhaust ventilation from the kitchens and sanitary facilities should be provided through channels with natural impulse, while it is allowed to combine the channels of one apartment (Table 1.4).

Table 1.4. Estimated temperatures and air exchange rates in residential buildings.

Type of roomInternal air temperature tin,CExhaust m3/h per 1m2 area
Living room183
Kitchen1560
Bathroom2550
Lobby, staircase18
Elevator machine room, garbage chamber51
Non-residential ground floors with public service establishments183

Sanitary and hygienic qualities of housing

The sanitary and hygienic qualities of a home are also assessed by the degree of its protection from noise.

To protect apartments from the noise of internal equipment, first of all, planning means should be used, for example, separating elevator shafts, garbage chutes, stairs, and utility risers into an isolated area. Sanitary units and kitchens of apartments should be located adjacent to the staircase and elevator unit.

To reduce noise levels, it is necessary to use seals in the vestibules of doors and windows, noise suppressors in windows, sound-absorbing screens for loggia fences, sealing through holes in hidden electrical wiring and joints between internal structures. The noise level penetrating into residential premises at night (from 23 to 7 o'clock) should not exceed 30 dB, in the daytime (from 7 to 23 o'clock) - 40 dB.

Sound insulation of building envelopes can be determined by measuring the sound insulating ability of structures and comparing it with the standard. The obtained data should not exceed the indices of airborne noise insulation of enclosing structures Iв and the indices of the reduced level of impact noise under the ceiling Iу by more than 2-8 dB (Table 1.5).

Table 1.5. Sound insulation standards for building envelopes of residential buildings

Enclosing structures of residential buildingsNoise isolation index. dB
Air IvImpact Iу
Floors between apartments5067
Floors between apartments and the attic47
Overlappings between apartment premises and the first non-residential floors5567
Overlappings between apartment rooms and noisy rooms above them6067
Walls and partitions between apartments50
Walls between apartment spaces and noisy rooms60
Partitions between rooms in an apartment41
Entry doors of apartments opening into staircases and lobbies30
Walls and ceilings separating the cultural and community service areas of dormitories from common areas45

When designing new enclosing structures, the calculation of sound insulation LA.pom is carried out using the formula LA.pom = LA.ter - ΔLA.ok. Where is L.A.

ter - sound level 2 m from the building envelope (for main streets and urban roads - 86 dB, for streets with residential buildings - 73 dB); ΔLA.

ok - reduction in sound level by the design of the window, protected from noise (for separate and close windows - 28 dB. for separate ones - 32 dB.

General requirements and calculation methods for noise protection are given in SNiP P-12-77 (Noise Protection).

Design and calculation of multi-storey civil buildings and their elements.

Applications

  1. List of basic designations
  2. Bibliography

Source: https://stroyremkom.ru/biblioteka/proyektirovaniye-zdaniy/sanitarno-tekhnicheskiye-trebovaniya-k-zhilym-zdaniyam.html

Type of room located in a building or structure

The Housing Code of the Russian Federation defines residential premises as real estate that is isolated and meets the requirements for permanent residence. It must meet sanitary and technical standards.

A residential premises may consist of several parts, and its total area is calculated as the sum of all these parts, including premises that are used as auxiliary ones (satisfying household and other human needs). Balconies, loggias, verandas and terraces are not included.

Types of premises classified as residential:

  • residential buildings, parts of residential buildings;
  • apartments, parts of apartments;
  • rooms.

Premises as a rental object

Due to the fact that the Civil Code of the Russian Federation (hereinafter referred to as the Civil Code of the Russian Federation) does not contain separate rules on the rental of premises, some provisions of § 4 Ch. 34 of the Civil Code of the Russian Federation on the rental of buildings and structures.

This practice is certainly logical, since a room is a part of the same buildings or structures that has structural boundaries (Article 2 of the Law “Technical Regulations on the Safety of Buildings and Structures” dated December 30.

2009 No. 384-FZ).

When concluding any contract, its subject must be agreed upon (Article 432 of the Civil Code of the Russian Federation) as an essential condition. Within the meaning of Art. 650 of the Civil Code of the Russian Federation, the subject of a lease agreement for non-residential premises is the property transferred under it. Therefore, the text must clearly identify the latter.

In order to clearly identify the object, you should use information from the Unified State Register of Real Estate, which is presented in the form of an extract.

And already at this stage, for the first time, we determine the intended purpose of the premises by differentiating objects into residential, i.e., suitable for permanent residence of people, and non-residential, i.e., not intended for the continuous presence of citizens in them (sub.

10 clause 5 art. 8 of the Law “On State Registration of Real Estate” dated July 13, 2015 No. 218-FZ).

Since the topic of our article is non-residential premises, further we will deal with the issue of dividing only this category of objects according to their intended purpose.

Non-residential premises

In the order of the Ministry of Land Construction of the Russian Federation, non-residential premises are defined as intended and used in the production, trade, warehouse, administrative and other areas of the building.

Since the functional purpose of non-residential premises can be different, they are divided into production, administrative, retail, warehouse, etc.

Like residential, non-residential premises can consist of several parts (rooms).

Industrial (commercial) premises - real estate that is located in a structure or building specifically designed for this type of activity. Basically, labor activities related to various types of enterprise production are carried out in these buildings.

Administrative premises are real estate intended for the functioning of offices of a state, non-state, economic or other institution and organization.

Retail space is another type of commercial premises used for selling services or goods.

Warehouse – real estate intended for storing and storing large volumes of goods.

List of groups by purpose

Non-residential premises are a part of a building in which people cannot permanently reside; they can be used for commercial and administrative purposes. On this basis there are office, warehouse, hotel, garage, retail and industrial facilities.

Commercial real estate has its own classification, which depends on the level of quality.

According to their purpose, such buildings are divided into those that are used to generate income (commercial) and those that create conditions for generating profit (industrial and industrial).

Categories of premises

According to the state classification of the Russian Federation, all premises are divided into the following categories:

  • 1st: recreation rooms in which a person is at rest;
  • 2nd: premises for studying or mental work;
  • 3rd “a” category: premises in which there is a regular mass gathering of people in a sitting position without clothes for the street;
  • 3rd “b”: similar to category 3 “a”, only people in it are in street clothes;
  • 3rd “c” category: a room with a regular mass gathering of people who stand without street clothes;
  • 4th: room used for sports;
  • 5th category: a room in which a person is scantily clad (locker room, doctor's office, treatment room, etc.);
  • 6th: a room in which a person is temporarily (wardrobe, staircase, corridor, bathroom, pantry, lobby, etc.).
Rating
( 2 ratings, average 4 out of 5 )
Did you like the article? Share with friends: